3 unit parameters command and queries – Comtech EF Data CRS-500 User Manual
Page 174

CRS-500 1:N Redundancy System
Revision 2
Serial-based Remote Product Management
MN-CRS500
9–14
9.5.3 Unit Parameters Command and Queries
Parameter Type
Command
(Code and
qualifier)
Arguments for
Command or
Response to
Query
Description of arguments
(Note that all arguments are ASCII numeric codes, that
is, ASCII codes between 48 and 57)
Response to Command
(Target to controller)
Query
(Code and
qualifier)
Response to query
(Target to controller)
Firmware Boot
From Slot
BFR=
1 byte, value of 1
to 3
Command or Query.
Sets or returns the bulk firmware slot to boot from in the
form x, where:
1=Firmware is Slot #1
2=Firmware is Slot #2
3=Latest Firmware (most recent release date)
BFR=
BFR?
BFR*
BFR#
BFR?
BFR=x
(see description of
arguments)
Current
Firmware Image
IMG=
1 byte, value of 1
or 2
Query Only.
Returns the active firmware image in the form x, where:
1=Bulk Image #1 currently active
2=Bulk Image #2 currently active
IMG=
IMG?
IMG*
IMG#
IMG?
IMG=x
(see description of
arguments)
IP Address
IPA=
20 bytes
Command or Query.
Sets or returns the IP address and network prefix for the
10/100 BaseTx Ethernet management port, in the form
xxx.xxx.xxx.xxx/yy, where:
xxx.xxx.xxx.xxx is the IP address, and
yy is the network prefix (00..31)
Example: IPA=010.006.030.001/24, means set IP address
on the switch to 10.6.30.1 with a subnet mask of 24.
IPA=
IPA?
IPA*
IPA#
IPA?
IPA=xxx.xxx.xxx.xxx/yy
IP Gateway
IPG=
15 bytes
numerical
Command or Query.
Sets or returns the IP Gateway Address for the Ethernet
management port in the form aaa.bbb.ccc.ddd, where
(permitted ranges are specified, but they cannot all be zero):
aaa 0-223
bbb 0-255
ccc 0-255
ddd 0-255
Notes:
1. The IP Gateway address must be on the same subnet
as the IP Address.
2. The IP Gateway address can be cleared by setting it
to 0.0.0.0
Example: IPG=010.006.030.001
IPG=
IPG?
IPG*
IPG#
IPG?
IPG=xxx.xxx.xxx.xxx
(see description of
arguments)