7.2.2.3 SELECT: Status
STATUS: Alarms Events
Temp Types Comms
Use the ◄ ► arrow keys to select Alarms, Events, Temp, Types, or Comms, and then press
ENTER.
7.2.2.3.1
STATUS: Alarms
The following are examples of possible switch status displays, along with suggestions to assist
you in diagnosing the reason for the fault.
Example 1:
Switch Alarm: NONE
There are no faults. The front panel LED “Unit Status” should be green.
Example 2:
Switch Alarm:
PSA 12V under/over
There is a fault. Power Supply “A” is under/over voltage. The front panel LED “Unit Status” will
be red.
Suggestions:
•
Ensure the power supply cord is connected and the power switch is ON.
•
Replace the defective power supply module.