Comtech EF Data CRS-500 User Manual
Page 177

CRS-500 1:N Redundancy System
Revision 2
Serial-based Remote Product Management
MN-CRS500
9–17
Parameter Type
Command
(Code and
qualifier)
Arguments for
Command or
Response to
Query
Description of arguments
(Note that all arguments are ASCII numeric codes, that
is, ASCII codes between 48 and 57)
Response to Command
(Target to controller)
Query
(Code and
qualifier)
Response to query
(Target to controller)
Clear All Stored
Events
CAE=
None
Command only.
Instructs the unit to clear all Stored Events.
This command takes no arguments.
CAE=
CAE*
N/A
N/A
Date
DAY=
6 bytes, numerical Command or Query.
Sets or returns the date, in the international date convention
form ddmmyy, where:
dd = day of the month, between 01 and 31,
mm = month of the year, between 01 and 12, and
yy = year, between 97 and 96 (1997 to 2000, then 2000
to 2096)
Example: DAY=240457 would be April 24, 2057.
DAY=
DAY?
DAY*
DAY?
DAY=ddmmyy
(see description of
arguments)
Equipment ID
N/A
4 bytes, alpha-
numeric
Query only.
Returns equipment identification information in the form
xxxx.
Example: S500
N/A
EID?
EID=xxxx
(see description of
arguments)
Firmware
information
N/A
100 bytes
Query only.
Returns firmware information for Image 1 (bulk1), Image 2
(bulk2), and Image 3 (bootrom):
Example: FRW?1
Fw/12864-,1.1.1,04/01/07
N/A
FRW?1
FRW?2
FRW?3
FRW=xxx…xxx
(see description of
arguments)
Managed Modem
Type
N/A
4 bytes,
alphanumeric
Query only.
Returns information concerning the model of the Redundant
Modem attached in the form xxxx, where:
0625 = CDM-625
5650 = SLM-5650
565A = SLM-5650A
750 = CDM-750
N/A
MOD?
MOD=xxxx
(see description of
arguments)
NTP enable /
disable
NEN=
1 byte, value of 0,
1
Command or Query.
Sets or returns the NTP status in the form x, where:
0 = Disabled
1 = Enabled
Example: NEN=1 (enables NTP)
NEN=
NEN?
NEN?
NEN=x
(see description of
arguments)