Comtech EF Data CRS-500 User Manual
Page 179

CRS-500 1:N Redundancy System
Revision 2
Serial-based Remote Product Management
MN-CRS500
9–19
Parameter Type
Command
(Code and
qualifier)
Arguments for
Command or
Response to
Query
Description of arguments
(Note that all arguments are ASCII numeric codes, that
is, ASCII codes between 48 and 57)
Response to Command
(Target to controller)
Query
(Code and
qualifier)
Response to query
(Target to controller)
Retrieve Next 5
unread Stored
Events
N/A
80 bytes
Query only.
Returns the oldest 5 Stored Events that have not yet been
read over the remote control in the form
[cr]Sub-body[cr]Sub-body[cr]Sub-body[cr]Sub-body[cr]Sub-
body, where:
Sub-body = KLMddmmyyhhmmss, where:
K is the fault/clear indicator, where
F = Fault, C = Clear, I = Info
L is the faulting/clearing unit, where the values can be:
1,2,...9 indicating traffic modems 1,2...9;
A=modem 10
B=Redundant Modem
C=Switch
D=Info
M is the fault code, where value depends on faulting unit:
Switch codes are 1 to F, indicating the position (1-15) of
the fault within the Switch FLT string.
Modem codes are:
1= Unit, 2= Rx traffic, 3= Tx traffic
Info codes are:
0= Power off, 1= Power on, 2= Log cleared
ddmmyy is the date of the event (international format).
hhmmss is the time of the event.
Notes:
1. If there are no new events, the unit replies with RNE*.
2. If fewer than 5 events remain, the last positions are
filled with zeroes.
N/A
RNE?
RNE=[cr]KLMddmmyyhh
mmss[cr]KLMddmmyyhh
mmss[cr]KLMddmmyyhh
mmss[cr]KLMddmmyyhh
mmss[cr]KLMddmmyyhh
mmss
(see description of
arguments)