AMETEK ASD Series User Manual
Page 97

Sorensen ASD Series
Programming: Digital Interface Control
M551177-01 Rev A
4-39
Parameter
Description
Trigger group
Trigger
Configures the trigger threshold.
Delay
Sets the delay from the beginning of the sample to the
trigger point.
Positive slope
Causes the trigger event to occur on a positive
transition through the trigger threshold.
Negative slope
Causes the trigger event to occur on a negative
transition through the trigger threshold.
Other controls
Scope1
Allows the operator to select a predefined signal from
the power supply for Channel 1 of the scope and
configures the other parameters for this signal.
Scope2
Allows the operator to select a predefined signal from
the power supply for Channel 2 of the scope and
configures the other parameters for this signal.
Decimation
Configures the sampling rate of the scope. 1 = 125 Hz;
2 = 62.5 Hz; 3 = 61.25...
Missed Data
This box turns red when there is scope data from the
power supply that has been missed by the program
Continuous Update
When this control is checked, the scope continues to
sample and append data to the scope window until the
scope is stopped; when unchecked the scope takes
one sample and stops.
trigger and
continuous with double
buffer
radio buttons to select whether the scope triggers on
Channel 1, triggers on Channel 2 or takes continuous
samples with no trigger.
Shift
Configures how many bits to shift that channel’s data to
the right.
IQ
Configures the IQ used by the data on a channel.
(converts IQ-formatted decimal numbers to floating
point).
Long
Checked indicates that the scope variable is a 32-bit
variable. Unchecked indicates that the scope variable is
a 16-bit variable.
Configure
Sends the current settings to the power supply so it can
configure its internal scope.
Update Data [Stop Update] Begins reading scope data from the power supply or to
stop reading data from the power supply in Continuous
Update mode