Sorensen ASD Series
Programming: Digital Interface Control
M551177-01 Rev A
4-47
4.6.5 MASTER CONTROLS PAGE
Unit Readback group
Current
Indicates the current readback of the power supply output
in amps
Voltage
Indicates the voltage readback of the power supply output
in volts
Power / Process
Indicates the power or process readback of the power
supply output in watts or process units (configured in the
ProcessAIConfig window).
Load Resistance
Indicates the resistance of the load connected to the
power supply output in ohms
Estimated Temperature
Indicates the temperature of the load connected to the
power supply in ºC, this value is calculated by the program
using the temperature coefficients assigned in the
Temperature Coefficients window
Energy Meter
Accumulates the total energy output by the power supply
since the last time the energy meter was reset in kW•s
Digital Outputs group
Note: a black control indicates true and a white control
indicates false.
VMode
If control is black and IMode control is white, the power
supply output is in voltage control mode.
IMode
If control is black and Vmode control is white, the power
supply output is in current control mode.