Sorensen ASD Series

Programming: Digital Interface Control

M551177-01 Rev A

4-47

4.6.5 MASTER CONTROLS PAGE

Unit Readback group

Current

Indicates the current readback of the power supply output
in amps

Voltage

Indicates the voltage readback of the power supply output
in volts

Power / Process

Indicates the power or process readback of the power
supply output in watts or process units (configured in the
ProcessAIConfig window).

Load Resistance

Indicates the resistance of the load connected to the
power supply output in ohms

Estimated Temperature

Indicates the temperature of the load connected to the
power supply in ºC, this value is calculated by the program
using the temperature coefficients assigned in the
Temperature Coefficients window

Energy Meter

Accumulates the total energy output by the power supply
since the last time the energy meter was reset in kW•s

Digital Outputs group

Note: a black control indicates true and a white control
indicates false.

VMode

If control is black and IMode control is white, the power
supply output is in voltage control mode.

IMode

If control is black and Vmode control is white, the power
supply output is in current control mode.