Programming: Digital Interface Control

Sorensen ASD Series

4-26

M551177-01 Rev A

4.5.5 SUPERVISORY FAULT CODES

Table 4-17 presents the supervisory fault codes for the Master controller,
and Table 4-18 presents the supervisory fault codes the Modules.

Table 4-17. Master Supervisory Fault Codes

Code

Name

Description

0x1

SUPERVISORY_I_BIAS

Internal circuits OCP

0x10

SUPERVISORY_CAN

Issue with internal/external communication bus

0x80

SUPERVISORY_LIN

Issue with internal communication bus

0x100

SUPERVISORY_MODBUS_BUFFER_FULL

The received Modbus packet is too big

0x200

SUPERVISORY_MODBUS_ERROR

Issue with Modbus communication, usually because
got to many packets

0x400

SUPERVISORY_SPI_ADC_BUSY

Communication issue with analog interface ADC.

0x800

SUPERVISORY_ADC_CONFIGURATION

Analog interface ADC was not properly configured.

0x1000

SUPERVISORY_MB_MODULE_QUERY_ERROR

Issue with the module query Modbus command.

0x2000

SUPERVISORY_FAULT_WATCHDOG

Microprocessor watchdog.

0x4000

SUPERVISORY_FLASH_WRITE_ERROR

There was an error writing internal Flash memory.

0x8000

SUPERVISORY_COMMAND_ERROR

not used

0x10000

SUPERVISORY_FW_UPDATE_NOT_COMPLETE

The firmware update process was not successfully
completed.

0x20000

SUPERVISORY_MASTER_NOT_CALIBRATED

The controller was not calibrated or does not have the
calibration coefficients loaded. It will use default values.

0x40000

SUPERVISORY_FLASH_CSM

Problem writing Flash memory because it is locked.

0x80000

SUPERVISORY_REDUNDANT_OUTPUT_ON

One of the redundant output enable circuits may have
a failure.

0x100000

SUPERVISORY_INCORRECT_HARDWARE_VERSION

The hardware version configured in the firmware is not
correct.

0x200000

SUPERVISORY_SPI_ADC_TIMEOUT

The external ADC for the analog interface has not
responded.

0x400000

SUPERVISORY_V_BIAS_5V

The 5V internal supply does not meet the
requirements.

0x800000

SUPERVISORY_V_BIAS_24V

The 24V internal supply does not meet the
requirements.

0x1000000

SUPERVISORY_SWITCH_READ_PROBLEM

the controller reading of the configuration switches is
not reliable

0x2000000

SUPERVISORY_ETHERCAT_FAILED_INIT

Only EtherCAT board

0x4000000

SUPERVISORY_WRONG_MASTER_ID

The master ID that was assigned is not compatible with
that firmware or hardware