3.5.2 EXTERNAL VOLTAGE PROGRAMMING USING A

0-10 VDC VOLTAGE SOURCE

A DC voltage source for remote voltage programming is connected
between V_PROG (terminal 12 on digital option board, terminal 15 on SG
compatible option board, or terminal 9 on EtherCAT Option Board) and the
return terminal AGND (terminal 9 on digital option board, terminal 20 on
SG compatible option board, or terminal 5 on EtherCAT Option Board).

The voltage coefficient for 10V remote voltage programming is 10 volts =
100% of rated output voltage. See Figure 3-12 to Figure 3-14 for
connection requirements.

1

13

25

14

AGND

V_PROG

9

12

0-10V

Voltage source

+

-

Figure 3-12. Remote Voltage Programming Using 0-10 VDC Voltage Source (Digital

Option Board)

1

13

25

14

+

-

15

20

0-10V

Voltage source

V_PROG

AGND

Figure 3-13. Remote Voltage Programming Using 0-10 VDC Voltage Source (SG

compatible Option Board)