Sorensen ASD Series

Overview

M551177-01 Rev A

1-23

1.2.2 ELECTRICAL CHARACTERISTICS

The voltage accuracy specifications are valid only with remote sense connected.

Parameter

Specification

Input

Voltage Ranges

342 VAC to 440 VAC (model D). Nominal rating is 380/400 VAC
432 VAC to 528 VAC (model E). Nominal rating is 480 VAC

Frequency

Rated 47 through 63 Hz

Efficiency

>91% (typical), nominal line, full load.

Phases

3

–phase, 3–wire plus ground. Not phase rotation sensitive. Neutral

not used.

Max Current, per phase, low
line

400/380 VAC

480 VAC

10kW unit (1 module)

21 Arms

17 Arms

20kW unit (2 modules)

42 Arms

33 Arms

30kW unit (3 modules)

63 Arms

50 Arms

Current Inrush

200A Typical

Power Factor

>0.9 @ Full Load and at nominal line

Brownout Provisions

Designed to meet SEMI F47-0706, S3, S8, S14 at nominal input
voltages

Output

Voltage Output

Noise (pk-pk)*
10kW and
20kW units

Noise (RMS)**
10kW and
20kW units

Noise (pk-pk)*
30kW unit

Noise (RMS)**
30kW unit

40Vdc

300mV

80mV

150mV

40mV

60Vdc

300mV

80mV

150mV

40mV

*

Measured at the output terminals, with 1uF in parallel with supply operating at full load and nominal input line voltage.

**

RMS noise is measured directly across the output terminal with supply operating at full load and nominal input line voltage.

Sense

To compensate load cables voltage drop, units can generate 2%
additional voltage at full scale of output voltage.

Load Regulation (Specified at no load to full load change, nominal AC input)

Voltage

0.1% of maximum output voltage / current

Current

0.1% of maximum output voltage / current

Line Regulation (Specified ±10% of nominal AC input, constant load)

Voltage

0.05% of maximum output voltage / current

Current

0.05% of maximum output voltage / current

Transient Response

A 50% step load will recover to within 0.75% of original value within 1
ms.

Stability

±0.05% of set point over 8 hours at fixed line, load, and temperature,
after 30-minute warm-up