1.2.2 ELECTRICAL CHARACTERISTICS
The voltage accuracy specifications are valid only with remote sense connected.
Parameter
Specification
Input
Voltage Ranges
342 VAC to 440 VAC (model D). Nominal rating is 380/400 VAC
432 VAC to 528 VAC (model E). Nominal rating is 480 VAC
Frequency
Rated 47 through 63 Hz
Efficiency
>91% (typical), nominal line, full load.
Phases
3
–phase, 3–wire plus ground. Not phase rotation sensitive. Neutral
not used.
Max Current, per phase, low
line
400/380 VAC
480 VAC
10kW unit (1 module)
21 Arms
17 Arms
20kW unit (2 modules)
42 Arms
33 Arms
30kW unit (3 modules)
63 Arms
50 Arms
Current Inrush
200A Typical
Power Factor
>0.9 @ Full Load and at nominal line
Brownout Provisions
Designed to meet SEMI F47-0706, S3, S8, S14 at nominal input
voltages
Output
Voltage Output
Noise (pk-pk)*
10kW and
20kW units
Noise (RMS)**
10kW and
20kW units
Noise (pk-pk)*
30kW unit
Noise (RMS)**
30kW unit
40Vdc
300mV
80mV
150mV
40mV
60Vdc
300mV
80mV
150mV
40mV
*
Measured at the output terminals, with 1uF in parallel with supply operating at full load and nominal input line voltage.
**
RMS noise is measured directly across the output terminal with supply operating at full load and nominal input line voltage.
Sense
To compensate load cables voltage drop, units can generate 2%
additional voltage at full scale of output voltage.
Load Regulation (Specified at no load to full load change, nominal AC input)
Voltage
0.1% of maximum output voltage / current
Current
0.1% of maximum output voltage / current
Line Regulation (Specified ±10% of nominal AC input, constant load)
Voltage
0.05% of maximum output voltage / current
Current
0.05% of maximum output voltage / current
Transient Response
A 50% step load will recover to within 0.75% of original value within 1
ms.
Stability
±0.05% of set point over 8 hours at fixed line, load, and temperature,
after 30-minute warm-up