3.3.5 ANALOG CONTROL CONNECTOR (J1)

The ANALOG CONTROL connector on the rear panel allows the unit to be
configured for different operating configurations: digital and analog current
programming, digital and analog voltage programming, current and
voltage output monitoring, output enable/disable, etc. The setup and
operating requirements of each configuration are provided in Sections 3.4
through 3.9.

I

SOLATED

A

NALOG

C

ONTROL

The Isolated Analog Control uses the Analog Control connector (J1). This
option fully isolates remote control signals and allows control of units not
connected to a common ground. Control ground is isolated from power
ground, which protects against potential damage from systems with high
electrical noise or large ground loop currents. The isolated analog control
is standard on digital option board, SG compatible board, and EtherCAT
option.

CAUTION!
This option is not intended to allow operation of the power supply at
excessive voltages. Refer to Section 2 INSTALLATION for maximum
terminal voltages.


Figure 3-2 shows the J1 connector's pin-out diagram. Refer to Table 2-1,
Table 2-2 and Table 2-3 for the ANALOG CONTROL connector
designations and functions:

Figure 3-2. ANALOG CONTROL Connector (J1) Pin-out