beautypg.com

AMETEK ASD Series User Manual

Page 89

background image

Sorensen ASD Series

Programming: Digital Interface Control

M551177-01 Rev A

4-31

4. To configure the Serial Port Properties:

a. Select the appropriate choices from the drop-down buttons, described as

follows:

Port:

Specify the computer COM port to make the
serial socket connection.

Baud Rate:

Should always be set to 230400 bits / sec for
Modbus serial communications with the power
supply.

Data Bits:

Should always be set to 8 bits for Modbus
serial communications with the power supply.

Parity:

Should always be set to None for Modbus
serial communications with the power supply.

Stop Bits:

Should always be set to 1 for serial
communications with the power supply.

Flow Control:

Should always be set to None for serial
communications with the power supply.

Modbus Slave
Address:

Specify the Modbus slave address used by the
power supply.

Note: Because several power supplies can be
connected to one serial Modbus connection the
slave address must match that of the power supply.

b. Choose to click any of the three buttons at the bottom as follows:

 Click Restore Defaults to return the serial port properties to their

default settings.

 Click Ok to accept the settings shown and return to the previous

window

 Click Cancel to return to the previous page without implementing any

changes to the settings.

c. Continue to Step 5.