Sorensen ASD Series

2-26

M551177-01 Rev A

For every module output without bus bar installed, two 3/8-16 x
1.00” brass screws, four 3/8 flat brass washer, two 3/8 split lock
brass washer, and two 3/8-16 brass nuts.

Black screw, 10-32UNC-2B x ½", front panel rack fastener:

10-30 kW: 4 ea

Note: If any of these parts are missing, please contact Customer Service
at 858-458-0223 (local) or 1-800-733-5427 (toll free).

2.3

LOCATION AND MOUNTING

WARNING!

To reduce the risk of fire or electrical shock, install the ASD Series unit in a
temperature and humidity controlled indoor area, free of conductive contaminants.

CAUTION!

The unit should not be installed in a raised ambient temperature greater than
50°C.

CAUTION!

This unit is intended for installation in a protected environment. No user
serviceable parts inside. Service to be performed by qualified personnel only.

CAUTION!

Ensure that the concentration of ozone is limited to a safe value. The
recommended long-term exposure limit for ozone is 0.1 PPM (0.2 mg/m

3

).

BURN HAZARD!

Hot Surface Warning. Allow to cool before servicing.

CAUTION!
A minimum three-person lift is required for the ASD Series unit, which
weighs up to 125 lbs (57kg) depending on the model.

Please refer to sections 2.8 and 2.9 for dimensional and installation
drawings, respectively.

2.3.1 RACK

The ASD Series models are designed for mounting in a standard 19-inch
equipment rack. If additional instrumentation is mounted in the rack, no
additional clearance is required above or below units in the ASD Series.

1. Support the unit using rack mount slides or appropriate L brackets

Suggested rack mount slide kit: Jonathan P/N 370EZ-28

2. Secure the unit in place using the screws provided.