AMETEK ASD Series User Manual
Page 107

Sorensen ASD Series
Programming: Digital Interface Control
M551177-01 Rev A
4-49
MB Address
MODBUS address of the power supply’s master controller.
Fault Code
Displays the system fault bits of the power supply
Fault Description
Displays descriptions of the system fault of the power
supply
Supervisory Fault
Displays the supervisory fault bits of the power supply’s
master controller; if the cursor is held over this control a
tool tip will be shown which gives descriptions of the
supervisory fault bits
Supervisory Warning: indicates the supervisory warning bits of the power supply’s
master controller; if the cursor is held over this control a tool tip will be shown which
gives descriptions of the supervisory warning bits
Setpoints group
allows control and monitoring of the power supply’s
current, voltage and power / process setpoints. Digital: If
the power supply’s output is turned on by this program
through digital programming these sliders will change the
setpoints of the power supply. Analog: If the power supply
is turned on through the analog interface then these sliders
will monitor the analog setpoints signals being read by the
analog interface of the power supply.
Setpo
int Slid
er
Mini
mum
Setp
oint
Maxim
um S
etpoin
t
Mo
dbu
s S
etp
oint
Rea
dba
ck
Setpoint Control Elements:
Setpoint Slider
In digital programming the slider controls the setpoints
changes that are sent to the power supply. In analog
programming the slider mirrors the changes to the power
supply setpoints that are received by the power supply
analog interface.
Slider in leftmost position Setpoint is set to the minimum, which will be sent to the
power supply.
Slider in rightmost
position
Setpoint is set to the maximum, which will be sent to the
power supply.
Field to right of slider
Displays the MODBUS setpoint readback from the power
supply.