AMETEK ASD Series User Manual
Page 103

Sorensen ASD Series
Programming: Digital Interface Control
M551177-01 Rev A
4-45
P
ROCESS
AIC
ONFIG
W
INDOW
The ProcessAIConfig window allows the user to change the functionality
of the analog interface setpoints depending on the requirements of their
process. It also allows the user to define the units and scaling of their
process feedback signal for more intuitive monitoring of the process.
Process Limit arrow
Click this arrow to toggle whether pin 11 of the
analog interface will be used to program a limit for
the maximum current / voltage that the power supply
can output during the process.
Process Setpoint arrow
Click on this arrow to toggle whether pin 12 of the
analog interface will be used for the process setpoint
or the digital communications Psetpoint register will
be used.
Process Calibration group
Calibrates the analog process feedback signal range
to real values of the process parameter being
measured by the transducer.
Cancel
Cancels all changes without accepting them and
closes the window.
Ok
Accepts the changes and closes the window.