Programming: Digital Interface Control
Sorensen ASD Series
4-54
M551177-01 Rev A
Page Component
Description/Function
Maximum
Maximum resistance or temperature setting
used for load resistance protection: if the
power supply load measurement goes above
this limit a system fault will occur.
Minimum
Minimum resistance or temperature setting
used for load resistance protection: if the
power supply load measurement goes below
this limit a system fault will occur.
Monitor
Displays the power supply readback of the
resistance or calculated temperature of the
output load
Update Settings
Clicking this button writes the settings for the
Minimum and Maximum resistance or
temperature limits to the power supply.
Cable Voltage Drop Protection group
Maximum
Maximum cable voltage drop limit of the power
supply while using remote voltage sensing, if
the cable voltage drop exceeds this limit a
system fault will be generated. (Remote Sense
Error in the Configuration page can be set to
disable the output of the power supply if this
fault occurs).
Monitor
Displays the cable voltage drop readback of
the power supply while using remote voltage
sensing.
Update Settings button
Click to write the displayed cable voltage drop
protection limit to the power supply.
Cable Resistance Protection group
Maximum
Maximum cable resistance limit of the power
supply while using remote sensing; if the
resistance across the cables exceeds this limit
a system fault will be generated. (Load Cable
Impedance in the Configuration page can be
set to disable the output of the power supply if
this fault occurs).
Monitor
Displays the cable resistance readback of the
power supply while using remote voltage
sensing.
Update Settings button
Click to write the displayed cable resistance
protection limit to the power supply.
Time and Date group (Real Time Clock Option)
Display
Shows the current time reading of the power
supply that includes the Real Time Clock
option.