AMETEK ASD Series User Manual
Page 85
Sorensen ASD Series
Programming: Digital Interface Control
M551177-01 Rev A
4-27
Table 4-18. Module Supervisory Fault Codes
Code
Name
Description
0x1 SUPERVISORY_THERMISTOR1
MOSFETs OTP
0x2 SUPERVISORY_THERMISTOR2
output diodes OTP
0x4 SUPERVISORY_HOTWIRE
internal airflow sensing detected low or too hot airflow
0x8 SUPERVISORY_FAN_SPEED
fan speed is below the minimum limit
0x10 SUPERVISORY_CAN
issue with internal/external communication bus
0x20 SUPERVISORY_TSHUNT
output shunt OTP
0x40 SUPERVISORY_AMBIENT
internal ambient OTP
0x80 SUPERVISORY_TDSP
microprocessor internal OTP
0x100 SUPERVISORY_ISHUNT_PEAK
output current OCP
0x200 SUPERVISORY_NO_MASTER
lost communication with master, didn't get any packet from the
master for a certain time
0x400 SUPERVISORY_LOW_VDC
input DC bus UVP, went below the absolute minimum
0x800 SUPERVISORY_COMMAND_ERROR
module could not achieve any of the requested setpoints
0x1000 SUPERVISORY_WRONG_LIN_ID
issue with the internal jumper that sets the module address
0x2000 SUPERVISORY_HW_OTP
redundant hardware OTP (MOSFETs or diodes)
0x4000 SUPERVISORY_LOW_LINE
input DC bus UVP, went to a value below the minimum, faults
after a certain time
0x8000 SUPERVISORY_VLINE_PEAK
input voltage high speed peak detection
0x10000 SUPERVISORY_VLINE_HIGH
input voltage high line detection
0x20000 SUPERVISORY_CT_PEAK
power converter primary circuit OCP
0x40000 SUPERVISORY_BIAS_PEAK
internal circuits OCP
0x80000 SUPERVISORY_HW_OCP_PEAK
output current redundant hardware OCP
0x100000 SUPERVISORY_OVP
output OVP
0x200000 SUPERVISORY_LIN
internal communication bus issue
0x400000 SUPERVISORY_DISCOVERY_ERROR
the module was not discovered
0x800000 SUPERVISORY_AC_FAULT_FROM_MASTER
AC input missing phase or low line fault
0x1000000 SUPERVISORY_WRONG_SERIAL_NUMBER
the module serial number of the module does not match the
backup one
0x2000000 SUPERVISORY_BIAS_FAULT
local bias UVP
0x4000000 SUPERVISORY_FAULT_WATCHDOG
microprocessor watchdog