AMETEK ASD Series User Manual
Page 116

Maintenance
Sorensen ASD Series
5-2
M551177-01 Rev A
An annual inspection of the ASD Series unit is recommended. Table 5-1
lists the visual inspection checks to be performed, and the corrective
action to be taken.
Table 5-1. Recommended Annual Inspection
Item
Inspect For
Corrective Action
External connector
plugs and jacks
Looseness, bent or corroded
contacts, damage or improper
seating in mating connector
Clean contacts with solvent
moistened cloth, soft bristle brush,
small vacuum, or low compressed
air.
Replace connectors damaged,
deeply corroded, or improperly
seated in mating connector.
Chassis, fan, and
extruded heatsinks
Dirt and corrosion
Clean with cloth moistened with
soapy water.
External electrical
wiring
Broken, burned or pinched
wire; frayed, worn or missing
insulation
Repair or replace defective wires.
External solder
connections
Corrosion, loose, cracked, or
dirty connections
Clean and resolder connections.
Dirt and moisture
buildup
Short circuits, arcing,
corrosion, overheating
Clean as required.
CAUTION!
For safe and continued operation of the ASD Series, always operate the
unit in a temperature and humidity controlled, indoor area, free of
conductive contaminants.