Maintenance

Sorensen ASD Series

5-2

M551177-01 Rev A

An annual inspection of the ASD Series unit is recommended. Table 5-1
lists the visual inspection checks to be performed, and the corrective
action to be taken.

Table 5-1. Recommended Annual Inspection

Item

Inspect For

Corrective Action

External connector
plugs and jacks

Looseness, bent or corroded
contacts, damage or improper
seating in mating connector

Clean contacts with solvent
moistened cloth, soft bristle brush,
small vacuum, or low compressed
air.

Replace connectors damaged,
deeply corroded, or improperly
seated in mating connector.

Chassis, fan, and
extruded heatsinks

Dirt and corrosion

Clean with cloth moistened with
soapy water.

External electrical
wiring

Broken, burned or pinched
wire; frayed, worn or missing
insulation

Repair or replace defective wires.

External solder
connections

Corrosion, loose, cracked, or
dirty connections

Clean and resolder connections.

Dirt and moisture
buildup

Short circuits, arcing,
corrosion, overheating

Clean as required.

CAUTION!
For safe and continued operation of the ASD Series, always operate the
unit in a temperature and humidity controlled, indoor area, free of
conductive contaminants.