Silica: 60 ppm maximum
TDS( Total Dissolved Solids): 800 ppm maximum
pH value: maintain slightly alkaline solution 7-8 pH
Conductivity: Less than 2000 micro-ohms/cm
Biocides: Use non-chloride based biocidal additives (bactericide,
algaecide) to kill microorganisms and prevent their growth.
Corrosion: Use corrosion inhibitors to minimize the negative effects of
corrosion. ( Nitrite borate or Sodium nitride).
2.5
INPUT/OUTPUT ELECTRICAL CONNECTIONS
WARNING!
High voltage present! Risk of electrical shock.
Ensure all areas are dry and that there is no leakage around the fluid inlet
or outlet.
Do not remove cover. Refer to qualified service personnel.
For permanently connected equipment, incorporate a readily accessible
disconnect device in the fixed wiring. For pluggable equipment, install the
socket outlet near the equipment and in an easily accessible location.
CAUTION!
Proper connection to the mains requires a circuit breaker or fuse with a rating of
25% over the maximum input line currents listed in Section 1.2.2.
WARNING!
Under no condition should the negative output terminal exceed 150V to earth
ground.