beautypg.com

Input/output electrical connections – AMETEK ASD Series User Manual

Page 26

background image

Installation

Sorensen ASD Series

2-28

M551177-01 Rev A

Silica: 60 ppm maximum

TDS( Total Dissolved Solids): 800 ppm maximum

pH value: maintain slightly alkaline solution 7-8 pH

Conductivity: Less than 2000 micro-ohms/cm

Biocides: Use non-chloride based biocidal additives (bactericide,

algaecide) to kill microorganisms and prevent their growth.

Corrosion: Use corrosion inhibitors to minimize the negative effects of

corrosion. ( Nitrite borate or Sodium nitride).

2.5

INPUT/OUTPUT ELECTRICAL CONNECTIONS

WARNING!
High voltage present! Risk of electrical shock.

Ensure all areas are dry and that there is no leakage around the fluid inlet
or outlet.

Do not remove cover. Refer to qualified service personnel.

For permanently connected equipment, incorporate a readily accessible
disconnect device in the fixed wiring. For pluggable equipment, install the
socket outlet near the equipment and in an easily accessible location.

CAUTION!

Proper connection to the mains requires a circuit breaker or fuse with a rating of
25% over the maximum input line currents listed in Section 1.2.2.

WARNING!

Under no condition should the negative output terminal exceed 150V to earth
ground.

Figure 2-2. Rear Panel Connections: Analog Interface

Figure 2-3. Rear Panel Connections: EtherCAT Interface