Sorensen ASD Series

Programming: Digital Interface Control

M551177-01 Rev A

4-15

Table 4-5. Command Register Bits

Bit

Field

Value

Description

1

ON

0
1

Turns off the unit.
Turns on the unit.

2

RESET_FAULT

0
1

No action.
Resets any faults.

3

REMOTE_SNS_DISABLE

0
1

Enables remote voltage sensing.
Disables remote voltage sensing.

4

ANALOG_CURRENT

0
1

Analog voltage programming mode.
Analog current programming mode.

5

IMPEDANCE_MONITOR

0
1

Disables output impedance monitoring.
Enables output impedance monitoring.

6

MODBUS_TIMEOUT

0
1

Disables monitoring of Modbus activity.
Enables monitoring of Modbus activity.

7

FOATING_POINT_ENABLED

0
1

Fractional register values use 32-bit IQ fractional encoding.
Fractional register values use 32-bit floating point encoding.

8

FDR_ENABLED

0
1

Flight Data Recorder periodic update disabled.
Flight Data Recorder periodic update enabled.

9

RESET_ENERGY_METER

0
1

No action.
Resets the energy meter to zero.

10

ANALOG_VOLTAGE_OVERRIDE

0
1

Analog Interface voltage set via external current or voltage signal.
Analog Interface voltage input disabled.

11

ANALOG_CURRENT_OVERRIDE

0
1

Analog Interface current set via external current or voltage signal.
Analog interface voltage input disabled.

12

ANALOG_POWER_OVERRIDE

0
1

Analog Interface power set via external current or voltage signal.
Analog Interface power input disabled.

13

DIGITAL PROGRAMMING MODE

0
1

Setpoints are taken from analog programming inputs.
Setpoints are taken from digital interface.

14

PROCESS CONTROL MODE

0
1

Standard modes: voltage/current/power.
Process control is active, modes: voltage/current/process.

15

DISABLE ANALOG SATURATION

0
1

Disabled analog inputs (bits 10, 11, 12) saturate to max setpoint.
Disabled analog inputs take setpoint from digital programming.

16

Not used