Page 20
Overview
Sorensen ASD Series
1-22
M551177-01 Rev A
1.2
SPECIFICATIONS
The following subsections provide environmental, electrical, and physical
characteristics for the ASD Series power supplies.
Note: Specifications are subject to change without notice.
Note: The ASD Series power supplies are intended for indoor use only. Please refer
to Section 2.3 for use/location requirements.
1.2.1 ENVIRONMENTAL CHARACTERISTICS
Parameter
Specification
Temperature
Coefficient
0.02%/
C of maximum output voltage rating for voltage set point.
0.03%/
C of maximum output current rating for current set point.
Ambient Temperature
Operating
0 to 50
C
Storage
-25
to 65
C
Cooling, by water
Flow (gpm)
1.5 nominal, 1.25 minimum, 1.75 maximum
NOTE:
Internal condensation must be prevented by ensuring
that the coolant is sufficiently high compared with the
ambient air dew point.
Temperature
25
C nominal, 20
C minimum, 30
C maximum
Pressure
80 PSI maximum
Pressure drop
Typical 12 PSI @ 1.5gpm per chassis
Humidity
Relative humidity up to 95% maximum, non-condensing
Altitude
Operating full power available up to 5,000 feet (1,524m),
derate 10% of full power for every 1,000 feet higher
non-operating to 40,000 feet (12,192m)
Agency Approvals
NRTL certified to UL/CSA 61010 and IEC/EN 61010-1, CE Compliant,
LVD Categories: Installation Category II: Pollution Degree 2; Class II
Equipment: for Indoor Use Only. Rack mount equipment requires proper
enclosure provided in end use. EMC Directive, EN 661326:1998