AMETEK ASD Series User Manual
Page 66

Programming: Digital Interface Control
Sorensen ASD Series
4-8
M551177-01 Rev A
Table 4-2. Module Controller FDR Data
Word size (bits) Variable
16
header
24
date/time
16
time_increment
16
module_status
32
supervisory_warning
32
supervisory_fault
16
Vsetpoint
16
Isetpoint
16
Vout
16
Ishunt
16
Vout_max
16
Ishunt_max
16
Vdcbus
16
Vin_peak
16
controller
16
CT_LS
16
Vbias
16
Ibias
16
Tamb
16
Tshunt
16
Tmosfets
16
Tdiodes
16
Txfmr
16
Vhotwire
16
fan_speed
16
spare_time
P
ERIODIC
D
ATA
R
ECORDING
A snapshot of the data is saved periodically at a period programmed by
the register “FDR_Period”, and also when a local warning or fault is
generated. The master controller has a real time clock (optional) that
keeps track of the date and time, so every entry is logged with this time
information. If the “FDR ENABLED” is set to “1”, the master controller
sends a periodic request to all to modules to save their local data to their
FDR memories. If any module has a local fault, it will immediately save it
to its local FDR with the last time information received from the master
plus a “time_increment”, specified in seconds.
Contact Customer Service for the necessary AMETEK software to
download the stored FDR information.