Table 4-2. Module Controller FDR Data

Word size (bits) Variable

16

header

24

date/time

16

time_increment

16

module_status

32

supervisory_warning

32

supervisory_fault

16

Vsetpoint

16

Isetpoint

16

Vout

16

Ishunt

16

Vout_max

16

Ishunt_max

16

Vdcbus

16

Vin_peak

16

controller

16

CT_LS

16

Vbias

16

Ibias

16

Tamb

16

Tshunt

16

Tmosfets

16

Tdiodes

16

Txfmr

16

Vhotwire

16

fan_speed

16

spare_time

P

ERIODIC

D

ATA

R

ECORDING

A snapshot of the data is saved periodically at a period programmed by
the register “FDR_Period”, and also when a local warning or fault is
generated. The master controller has a real time clock (optional) that
keeps track of the date and time, so every entry is logged with this time
information. If the “FDR ENABLED” is set to “1”, the master controller
sends a periodic request to all to modules to save their local data to their
FDR memories. If any module has a local fault, it will immediately save it
to its local FDR with the last time information received from the master
plus a “time_increment”, specified in seconds.

Contact Customer Service for the necessary AMETEK software to
download the stored FDR information.