Programming: Digital Interface Control
Sorensen ASD Series
4-56
M551177-01 Rev A
Page Component
Description/Function
Other Settings group
Expected Modules:
Sets the expected number of modules to be
discovered by the master controller.
Over Voltage Protection:
Sets the over-voltage limit of the modules.
Vsetpoint SRL:
Configures the maximum rate at which the
voltage setpoint can slew to a new value.
Isetpoint SRL:
Configures the maximum rate at which the
current setpoint can slew to a new value.
Modbus Timeout:
When Modbus Timeout is enabled on the
Master Controls tab, Modbus Timeout
configures the maximum interval between
Modbus communications packets before a
fault is generated.
Update Settings button
Click to write the Others Settings values to the
power supply.
Monitor Window group
Scroll Length
Adjusts the scale (in seconds) of the Monitor
Window horizontal axis in the Master Controls
page, when the Scrolling Data parameter is
checked.
Scrolling Data
When checked the monitor window data will
scroll and the horizontal scaling will be the
Scroll Length; when unchecked the monitor
window will continue to append new data until
the Clear Window button is clicked.
Clear Window button
Click with Scrolling Data checked to clear the
Monitor Window and begin appending fresh
data.
Upload Activation Code group
Code
If the digital communications of the power
supply are locked (per factory configuration),
the unique unlock code for that power supply
can be written here to unlock the digital
communications and give the full capabilities
(both analog and digital interface) of the power
supply.
Upload button
Click to uploadthe activation code displayed in
the Code field to the power supply to unlock
digital communications.