Programming: Digital Interface Control
M551177-01 Rev A
4-51
4.6.6 CONFIGURATION PAGE
The Configuration page is used to control whether system faults disable
the output of the power supply when they occur, it also is used to
configure the operation of the analog programming interface.
Shutdown Enable Bits
group
Each control in the Shutdown Enable Bits Group
sets that system fault to disable the output of the
power supply or to allow the output of the power
supply to continue. Black = disable the power
supply output if that fault occurs. White = continue
the power supply output even if that fault occurs.
Note: some of the faults are not configurable and always disable the output of the
power supply
Analog Interface
Configuration group
Note: clicking the controls in the Analog Interface
Configuration group toggles their setting: black =
true; white = false
4-20mA Programming
Black/True sets the analog interface inputs and
outputs to control and monitor the power supply
using current signals. White/false then the analog
interface inputs and outputs control and monitor the
power supply using 0-10V voltage signals.
Voltage Programming
Disable
Disables the analog voltage programming signal
and sets the voltage setpoint to either the full-scale
voltage or the digital voltage setpoint - depending
on the Disable Analog Saturate setting (below),.