set_write_data_mode()
April 2014
set_write_data_mode()
This nonblocking procedure sets the write_data_mode field for a transaction that is uniquely
identified by the transaction_id field previously created by the
procedure.
Note
You do not normally use this procedure in a slave test program.
Prototype
set_write_data_mode
(
write_data_mode: in integer;
transaction_id : in integer;
bfm_id : in integer;
path_id : in axi4_path_t; --optional
signal tr_if : inout axi4_vhd_if_struct_t
);
Arguments
write_data_mode
Write data mode:
AXI4_DATA_AFTER_ADDRESS (default);
AXI4_DATA_WITH_ADDRESS;
transaction_id
Transaction identifier. Refer to “
” on page 151 for more details.
bfm_id
BFM identifier. Refer to “
Overloaded Procedure Common Arguments
on page 151 for more details.
path_id
(Optional) Parallel process path identifier:
AXI4_PATH_0
AXI4_PATH_1
AXI4_PATH_2
AXI4_PATH_3
AXI4_PATH_4
Refer to “
Overloaded Procedure Common Arguments
tr_if
Transaction signal interface. Refer to “
” on page 151 for more details.
Returns
None