Set_read_or_write() – Altera Mentor Verification IP Altera Edition AMBA AXI4-Lite User Manual
Page 234
Mentor Verification IP AE AXI4-Lite User Guide, V10.3
234
VHDL Slave BFM
set_read_or_write()
April 2014
set_read_or_write()
This procedure sets the read_or_write field for a transaction that is uniquely identified by the
transaction_id field previously created by the
procedure.
Note
You do not normally use this procedure in a slave test program.
Prototype
set_read_or_write
(
read_or_write: in integer;
transaction_id : in integer;
bfm_id : in integer;
path_id : in axi4_path_t; --optional
signal tr_if : inout axi4_vhd_if_struct_t
);
Arguments
read_or_write
Read or write transaction:
AXI4_TRANS_READ = 0
AXI4_TRANS_WRITE = 1
transaction_id
Transaction identifier. Refer to “
” on page 151 for more details.
bfm_id
BFM identifier. Refer to “
Overloaded Procedure Common Arguments
on page 151 for more details.
path_id
(Optional) Parallel process path identifier:
AXI4_PATH_0
AXI4_PATH_1
AXI4_PATH_2
AXI4_PATH_3
AXI4_PATH_4
Refer to “
Overloaded Procedure Common Arguments
” on page 151 for
more details.
tr_if
Transaction signal interface. Refer to “
” on page 151 for more details.
Returns
None