Timer/Counter Control (TCON)
TF1
Bit 7
TR1
Bit 6
TF0
Bit 5
TR0
Bit 4
IE1
Bit 3
IT1
Bit 2
IE0
Bit 1
IT0
Bit 0
Timer 1 overflow flag. This bit indicates when timer 1 overflows its maximum count as defined
by the current mode. This bit can be cleared by software and is automatically cleared when the CPU
vectors to the timer 1 interrupt service routine.
0 = No timer 1 overflow has been detected.
1 = Timer 1 has overflowed its maximum count.
Timer 1 run control. This bit enables/disables the operation of timer 1.
0 = Timer 1 is halted.
1 = Timer 1 is enabled.
Timer 0 overflow flag. This bit indicates when timer 0 overflows its maximum count as defined
by the current mode. This bit can be cleared by software and is automatically cleared when the CPU
vectors to the timer 0 interrupt service routine or by software.
0 = No timer 0 overflow has been detected.
1 = Timer 0 has overflowed its maximum count.
Timer 0 run control. This bit enables/disables the operation of timer 0.
0 = Timer 0 is halted.
1 = Timer 0 is enabled.
Interrupt 1 edge detect. This bit is set when an edge/level of the type defined by IT1 is
detected. If IT1 = 1, this bit remains set until cleared in software or until the start of the external interrupt
1 service routine. If IT1 = 0, this bit inversely reflects the state of the INT1 pin.
Interrupt 1 type select. This bit selects whether the INT1 pin detects edge- or level-triggered
interrupts.
0 = INT1 is level triggered.
1 = INT1 is edge triggered.
Interrupt 0 edge detect. This bit is set when an edge/level of the type defined by IT0 is
detected. If IT0 = 1, this bit remains set until cleared in software or the start of the external interrupt 0
service routine. If IT0 = 0, this bit inversely reflects the state of the INT0 pin.
Interrupt 0 type select. This bit selects whether the INT0 pin detects edge- or level-triggered
interrupts.
0 = INT0 is level triggered.
1 = INT0 is edge triggered.
7
6
5
4
3
2
1
0
SFR 88h
TF1
TR1
TF0
TR0
IE1
IT1
IE0
IT0
RW-0
RW-0
RW-0
RW-0
RW-0
RW-0
RW-0
RW-0
R = Unrestricted read, W = Unrestricted write, -n = Value after reset