beautypg.com

Registering a master image for, The iv series externally -36 – KEYENCE IV Series User Manual

Page 94

background image

5-36

- IV Series User’s Manual (Field Network) -

Operating procedure of the data I/O communication

Registering a master image for the IV series externally

Master registration request

Master registration response

BUSY

(1) Execute a [Master registration request]. (0 → 1)
(2) You can check the input status in [Master registration response].

y

[BUSY] will change from 0 to 1 while the master image registration is in progress.

y

If the master image registration is unsuccessful, [Master registration failed] will change from 0 to 1.

y

If the master image registration is unsuccessful, [Warning] will switch from “0” to “1” and [Warning No.]
will be updated according to the failure details. For details, refer to “Warning code list” (Page 5-30).

y

You cannot register a master image from the PROFINET communication while the unit is in “Setting”
status.

y

If you wish to write the master registration data to the sensor ROM, set the [Write to ROM at external
master reg.] option to [Yes]. For details of the setting, refer to the “IV Series User’s Manual (Monitor /
PC Software)”.

5

Data I/O communication