Rockwell automation control logix series settings, Rockwell automation control logix series, Settings -8 – KEYENCE IV Series User Manual
Page 30
3-8
- IV Series User’s Manual (Field Network) -
Cyclic communication setting method
6
Select [Device comment edit window]
from the [Edit] menu in KV STUDIO.
The [Device comment edit] screen will appear.
Click [Details].
The [Register unit device] screen will appear.
7
Make sure that the [IV Series] checkbox is
ON in the [Select unit] field, and then
click the [Reg] button.
8
Select [PLC Transfer] from the [Monitor/
Simulator] menu of KV STUDIO.
Rockwell Automation Control Logix
series settings
This following explains the setting method when
using a Control Logix PLC.
1
Select the EtherNet/IP communication unit
to be connected with the IV series in
the I/O configuration of RsLogix5000, and
then right-click to select [New Module].
The [Select Module] screen will appear.
2
Click the [+] button next to Communications,
and then select EtherNET-MODULE (Generic
Ethernet Module) and click the [OK] button.
The [New Module] screen will appear.
3
Cyclic communication