beautypg.com

Data allocations in the data i/o communication, Control modules (plc → iv series), Command control – KEYENCE IV Series User Manual

Page 74: Data allocations in, The data i/o communication -16, Control modules (plc → iv series) -16, Command control -16, Data allocations in the data i/o communication 5

background image

5-16

- IV Series User’s Manual (Field Network) -

Data allocations in the data I/O communication

The PROFINET communication for the IV series is defined using the following modules:

y

Command Control Module

y

Command Status Bits Module

y

Device Result Bits Module

y

Device Status Words Module

y

Device Statistics Module

y

Position Adjust Result Module

y

Tool Result Module

Control Modules (PLC → IV series)

Control Modules are modules that write instructions from the PLC to the IV series.
The device map of the data allocated for the Control Modules is as shown below.
These parameters are responsible for the control instructions for the IV series, clearing of warnings and
handshake control.
For details of each parameter, refer to “Control Modules parameter details” (Page 5-20).

z

„

Command Control

Slot No.: 1
Module size: 12 bytes

Address

Bit7

Bit6

Bit5

Bit4

Bit3

Bit2

Bit1

Bit0

0

Reserved by system

Buffer

clear

request

Statistics

reset

request

Warning

clear

request

Program

switching

request

Master

registration

request

Trigger

request

1

Reserved by system

2

Reserved by system

Result

acquisition

complete

notification

3

Reserved by system

4 - 5

Program No.

6 - 11

Reserved by system

Data allocations in the data I/O communication

5

Data I/O communication