beautypg.com

Cyclic communication setting method, Setting the iv series, When settings on the monitor (iv-m30) – KEYENCE IV Series User Manual

Page 25: Cyclic communication setting method -3, Setting the iv series -3, When settings on the monitor (iv-m30) -3

background image

3-3

- IV Series User’s Manual (Field Network) -

Cyclic communication setting method

Cyclic communication setting method

This following explains the setting method when
using the cyclic communication.

y

To control the IV series using the EtherNet/IP

communication, select [Network connection] for

the sensor connection setting. When connected

directly, the field network settings will be greyed

out and disabled.

y

If you have modified the protocol settings, the

connection with the sensor will be terminated

and then restarted.

Setting the IV series

You can configure the following settings for the IV
series using the monitor (IV-M30) or IV-Navigator
(IV-H1).

When settings on the monitor (IV-M30)

Set the field network settings of the sensor to
[EtherNet/IP].

1

Tap the [Sensor Advanced] button on the

Sensor Setup Menu screen.

2

Tap the [Environmental] button, and then

the [Adv. Network Settings] button.

3

Tap the [Settings] button in the “Field

Network”.

4

Select [Ethernet/IP] for the protocol.

5

To enable the handshake control, select

[Enable].

y

When the protocol is set as [Disable],

this setting item is shaded and cannot be

selected.

y

When the data handshake control is set

as [Enabled], the status result will not be

updated until [Result acquisition complete

notice] (“Address2, Bit0” of Output Assembly)

is input.

“Operating procedure of the cyclic

communication” (Page 3-26)

6

After the setting is completed, tap the [OK]

button.

3

Cyclic communication