3-27

- IV Series User’s Manual (Field Network) -

Operating procedure of the cyclic communication

z

„

When a trigger is unsuccessful

Trigger request

Result of A

Warning No.

A

C

B

A

C

C

B

A

B

A

A

A

C

C

C

C

Result of C

Trigger response

Trigger failed

BUSY

Imaging status

Result update complete

Result available

Result No.

Warning

Overall judgment

Warning No.

(1) Execute a [Trigger request]. (0 → 1)
(2) If the trigger is valid, [Trigger response] will change from 0 to 1.
(3) [BUSY] will change from 0 to 1 when a trigger is input.
(4) [BUSY] will change from 1 to 0 when the judgment process ends.

The [Result update complete] BIT will be switched at this time; and [Overall judgment] will be updated.

(5) If you wish to output trigger errors, set the trigger error option to [Enabled].

If a trigger has been input while the trigger error option is set to [Enabled] and the unit is in “BUSY”
status, [Trigger failed] will change from 0 to 1 ignoring the trigger input. No judgment process will be
performed for trigger B.

(6) If the trigger input is unsuccessful, [Warning] will switch from “0” to “1” and [Warning No.] will be

updated to “65”. For details, refer to “Warning code list” (Page 3-23).

y

[Result update complete] will switch to “1” if its value was “0” after the previous judgment update (or

from “0” to “1” if the previous value was “1”).

y

[Result available] will switch from 0 to 1 at the timing when the first judgment process has been

confirmed; and the new value will be retained thereafter.

y

[Result No.] will be counted up each time the status result is updated. The upper limit value is 32767. If

the maximum value is exceeded, it will go back to 0 and start counting up again.

y

[Result No.] will also count the judgment process counts that were skipped due to the cyclic frequency

setting.

y

[Busy] and [Imaging] may be skipped in some cyclic frequency settings. It is therefore necessary to take

the imaging condition into consideration when setting the cyclic frequency.

y

[Number of trigger errors] will be counted up at the timing when the [Result updated] BIT is switched.

3