Overview of IV Series
Operation of the indicator light
Details on operations of the indicator light are
shown below.
1 2 3
4
5
1 PWR/ERR
Indicates the power supplying status to the
sensor and the error status of the sensor.
y
Green (ON) ...... Operating.
y
Green (Blink) .... Setting processing. Operation
is stopped. Blinks once a
second.
y
Red (ON) .......... Unrecoverable error has
occurred.
y
Red (Blink) ....... Recoverable error has
occurred.
y
Orange (Blink)... Flash LED has been required on
the PROFINET communication
I/O controller. Blinks 4 times
with a period of about a second.
y
(OFF) ............... Power is not supplied.
Adjusting the focusing position
(manual focus only).
2 OUT
Indicates the comprehensive result.
y
Green ............... Comprehensive result is “OK”.
y
Red .................. Comprehensive result is “NG”.
y
(OFF) ............... Setting processing.
Standby status until the first
judge finishes after starting the
operation or after switching
the program number.
y
Orange (Blink) ... Indicates the focusing status
while adjusting the focusing
position with the blinking speed
(manual focus type only).
Flash LED has been required on
the PROFINET communication
I/O controller. Blinks 4 times
with a period of about a second.
3 TRIG
Green light lights up (one-shot) according to
input of the internal or external trigger.
y
Orange (Blink)... Flash LED has been required on
the PROFINET communication
I/O controller. Blinks 4 times
with a period of about a second.
4 STATUS
Indicates the connecting status to the PC.
y
Green (ON) ...... Normally connected with monitor,
PC, EtherNet/IP communication
scanner, or PROFINET
communication I/O controller.
y
Green (Blink) .... IP address has been retrieved
but the sensor is not correctly
connected with monitor, PC,
EtherNet/IP communication
scanner, or PROFINET
communication I/O controller.
y
Red (Blink) ....... Timeout has occurred at the
communication with EtherNet/
IP communication scanner.
y
Red (ON) .......... IP address coincides with
another device.
y
(OFF) ............... IP address is not assigned.
Not correctly connecting with
PC.
y
Orange (Blink) .. Indicates the focusing status
while adjusting the focusing
position with the blinking speed
(manual focus type only).
5 LINK/ACT
Indicates the linking status within PC or
Ethernet switch.
y
Green (ON) ...... Normally linked.
y
Green (Blink) .... Normally linked, and the data
is sending/receiving.
y
(OFF) ............... Sensor is not normally linked.
1