Command control address 2 to 3: handshake control, Command control address 4 to 11: program no, Command control address 2 to 3 – KEYENCE IV Series User Manual
Page 79: Handshake control -21, Command control address 4 to 11, Program no -21
5-21
- IV Series User’s Manual (Field Network) -
Data allocations in the data I/O communication
z
Command Control Address 2 to 3: Handshake control
The Bits at Address 2 to 3 of the Command Control have the following functions:
Address
Bit
Item
Content
Data content
2
0
Result acquisition
complete notification
Permits the updating of the
status result.
0 : OFF
1 : ON
1 to 7 Reserved by system
---
---
3
0 to 7 Reserved by system
---
---
A result acquisition completion notice is used when handshake control is [Enabled].
Updating of the status result will be permitted when you request a result acquisition completion notice.
For details, refer to “Reading out the overall status result of the IV series (Handshake control [Enabled])”
(Page 5-34).
z
Command Control Address 4 to 11: Program No.
The Bits at Address 4 to 11 of the Command Control have the following functions:
Address
Bit
Item
Content
Data content
4 to 5
UINT Program No.
Stores the program No. when a
program switching is requested. 0 to 31
6 to 11
---
Reserved by system
---
---
5
Data I/O communication