Command control address 2 to 3: handshake control, Command control address 4 to 11: program no, Command control address 2 to 3 – KEYENCE IV Series User Manual

Page 79: Handshake control -21, Command control address 4 to 11, Program no -21

background image

5-21

- IV Series User’s Manual (Field Network) -

Data allocations in the data I/O communication

z

„

Command Control Address 2 to 3: Handshake control

The Bits at Address 2 to 3 of the Command Control have the following functions:

Address

Bit

Item

Content

Data content

2

0

Result acquisition

complete notification

Permits the updating of the

status result.

0 : OFF

1 : ON

1 to 7 Reserved by system

---

---

3

0 to 7 Reserved by system

---

---

A result acquisition completion notice is used when handshake control is [Enabled].
Updating of the status result will be permitted when you request a result acquisition completion notice.
For details, refer to “Reading out the overall status result of the IV series (Handshake control [Enabled])”
(Page 5-34).

z

„

Command Control Address 4 to 11: Program No.

The Bits at Address 4 to 11 of the Command Control have the following functions:

Address

Bit

Item

Content

Data content

4 to 5

UINT Program No.

Stores the program No. when a

program switching is requested. 0 to 31

6 to 11

---

Reserved by system

---

---

5