Cyclic communication setting method

There are many types of connections, and the connection available for each device are defined in the EDS
file.
The following shows the list of connections that are available in the IV series.

No

Connection name

Application type

I/O

Assembly

Instance

Size

(bytes)

RPI

1

Monitor Data And

External Input

(Monitor/External

input)

Exclusive Owner

This unit

→ Scanner

64H (100)

2 to 392

5 to 10000ms

Scanner

→ This unit

65H (101)

2 to 12

2

Monitor Data (Input

Only)

(Monitor data)

Input Only

This unit

→ Scanner

64H (100)

2 to 392

5 to 10000ms

Scanner

→ This unit

FEH (254)

0

When using the Keyence KV series (EtherNet/IP communication scanner), the names of the connections
with the IV series will be “Monitor/External Input” and “Monitor Data”. The relationship of each connection
name is as described below.
1 : Monitor Data And External Input → Monitor/External input
2 : Monitor Data (Input Only)

→ Monitor data

y

The trigger timings of each connection are controlled by the cyclic communications; and both the point-

to-point and Multicast connection types are supported.

y

If you wish to open “Exclusive Owner” and “Input Only” connections simultaneously, set the connection

type to “Multicast” and match the RPI and the size.

y

The details of each application type are as described below.

[Exclusive Owner]

y

This connection allows you to configure the data transmission from the scanner to the IV series, and

vice versa.

y

This connection type is used when the scanner will not only monitor the data of the IV series but also

provide external input to the IV series.

y

It is not possible for multiple scanners to open "Exclusive Owner" connections for a single IV series

unit.

[Input Only]

y

This connection only allows you to configure the data transmission from the IV series to the scanner.

y

This connection is used when the scanner will only monitor the data of the IV series.

y

Multiple scanners can simultaneously open “Input Only” connections for a single IV series unit.

y

If connections will be opened simultaneously from multiple scanners, set the connection type to

“Multicast” and match the RPI and the size.

3

Cyclic communication