beautypg.com

Handshake control [enabled, Siemens plc, Description of the reference program – KEYENCE IV Series User Manual

Page 103: Description of the reference program ... a-9

background image

A-9

- IV Series User’s Manual (Field Network) -

Reference program (PROFINET)

Handshake control [Enabled]

Siemens PLC

Network1

Network2

Network3

REQ

P

P

P

MOV

EN

IN

Result

ENO

OUT

Tool Score

Trigger

Result Ready

Result Ready

Result Ready Ack

Trigger Ack

Trigger

Result Ready Ack

Result Ready

z

„

Description of the reference program

z

z

Network1

Sets “REQ” to ON and executes “Trigger”.
“Trigger Ack” ON will set “Trigger” to OFF (“Trigger” will be retained until “Trigger Ack” becomes ON).

z

z

Network2

“Result Ready” ON will copy the data written in “Tool Score” to “Result”.

z

z

Network3

“Result Ready” ON will execute “Result Ready Ack”.
“Result Ready” OFF will set “Result Ready Ack” to OFF (“Result Ready Ack” will be retained until “Result
Ready” becomes OFF).