beautypg.com

Input assembly address 72 to 391: tool information, Input assembly address 52 to 71, Position correction information -18 – KEYENCE IV Series User Manual

Page 40: Input assembly address 72 to 391, Tool information -18

background image

3-18

- IV Series User’s Manual (Field Network) -

Data allocation in the cyclic communication

z

„

Input Assembly Address 52 to 71: Position correction information

The Bits at Address 52 to 71 of the Input Assembly have the following functions:

Address

Data

type*

Item

Content

Data content

52 to 53

UINT

Position correction tool

matching rate

Stores the matching rate of the

position correction tool.

0 to 100

54 to 55

UINT

Position correction tool

matching rate MAX

Stores the maximum matching

rate value of the position

correction tool.

0 to 100

56 to 57

UINT

Position correction tool

matching rate MIN

Stores the minimum matching

rate value of the position

correction tool.

0 to 100

58 to 59

UINT

Position correction tool

threshold

Stores the threshold value of the

position correction tool.

0 to 100

60 to 71

---

Reserved by system

---

---

* UINT : Unsigned 16-bit integer

UDINT : Unsigned 32-bit integer

Maximum and minimum matching rate values of the position correction tool will be reset in the same

manner as the statistics information.

If the position correction tool is not set, the data content will be “0”.

z

„

Input Assembly Address 72 to 391: Tool information

The Bits at Address 72 to 391 of the Input Assembly have the following functions:

Address

Data

type*

Item

Content

Data content

72 to 73

UINT

Tool 1 matching rate

Stores the matching rate of Tool

1.

0 to 999

74 to 75

UINT

Tool 1 matching rate MAX Stores the maximum matching

rate value of Tool 1.

0 to 999

76 to 77

UINT

Tool 1 matching rate MIN Stores the minimum matching

rate value of Tool 1.

0 to 999

78 to 79

UINT

Tool 1 lower limit value

Stores the lower threshold value

of Tool 1.

0 to 999

80 to 81

UINT

Tool 1 upper limit value

Stores the upper threshold

value of Tool 1.

0 to 999

82 to 91

---

Reserved by system

---

---

Thereafter, the information of tool 2, 3, ... 16 will be assigned for each 20-byte Address of Input Assembly.

* UINT : Unsigned 16-bit integer

UDINT : Unsigned 32-bit integer

y

Maximum and minimum matching rate values of the tool will be reset in the same manner as the

statistics information.

y

If the tool is not set, the data content will be “0”.

y

If the upper threshold value of the tool is not set, the data content of the tool’s upper limit value will be

“65535”.

3