Output assembly address 2 to 3: handshake control, Output assembly address 4 to 11: program no, Output assembly address 2 to 3 – KEYENCE IV Series User Manual
Page 43: Handshake control -21, Output assembly address 4 to 11, Program no -21
3-21
- IV Series User’s Manual (Field Network) -
Data allocation in the cyclic communication
z
Output Assembly Address 2 to 3: Handshake control
The Bits at Address 2 to 3 of the Output Assembly have the following functions:
Address
Bit
Item
Content
Data content
2
0
Result acquisition
complete notification
Permits the updating of the
status result.
0: OFF 1: ON
1 to 7 Reserved by system
---
---
3
0 to 7 Reserved by system
---
---
A result acquisition completion notice is used when handshake control is [Enabled].
Updating of the status result will be permitted when you request a result acquisition completion notice.
For details, refer to “Reading out the overall status result of the IV series (Handshake control [Enabled])”
(Page 3-28).
z
Output Assembly Address 4 to 11: Program No.
The Bits at Address 4 to 11 of the Output Assembly have the following functions:
Address
Data
type
Item
Content
Data content
4 to 5
UINT Program No.
Stores the program No. when a
program switching is requested. 0 to 31
6 to 11
---
Reserved by system
---
---
3