beautypg.com

KEYENCE IV Series User Manual

Page 33

background image

3-11

- IV Series User’s Manual (Field Network) -

Data allocation in the cyclic communication

Address

Bit7

Bit6

Bit5

Bit4

Bit3

Bit2

Bit1

Bit0

54 - 55

Position correction score MAX (Unsigned 16-bit integer)

56 - 57

Position correction score MIN (Unsigned 16-bit integer)

58 - 59

Position correction score Lower threshold (Unsigned 16-bit integer)

60 - 71

Reserved by system

72 - 73

Tool 1 score (Unsigned 16-bit integer)

74 - 75

Tool 1 score MAX (Unsigned 16-bit integer)

76 - 77

Tool 1 score MIN (Unsigned 16-bit integer)

78 - 79

Tool 1 lower threshold (Unsigned 16-bit integer)

80 - 81

Tool 1 upper threshold (Unsigned 16-bit integer)

82 - 91

Reserved by system

92 - 391

Tool 2 to 16 (Same as Tool 1)

The start address of tool number “n” is 72 + (n-1) x 20

3

Cyclic communication