Data i/o communication setting method, Setting the iv series, When settings on the monitor (iv-m30) – KEYENCE IV Series User Manual
Page 61: Data i/o communication setting method -3, Setting the iv series -3, When settings on the monitor (iv-m30) -3, Data i/o communication setting method 5
5-3
- IV Series User’s Manual (Field Network) -
Data I/O communication setting method
This following explains the setting method when
using the data I/O communication.
yTo control the IV series using the PROFINET
communication, select [Network connection] for the
sensor connection setting. When connected directly, the
field network settings will be greyed out and disabled.
y
The PROFINET function will stop if the scanner is
connected directly while the PROFINET function
is in use. To use the PROFINET function again,
you need to restart the sensor.
y
If you have modified the protocol settings, the
connection with the sensor will be terminated and
then restarted.
Setting the IV series
You can configure the following settings for the IV series
using the monitor (IV-M30) or IV-Navigator (IV-H1).
When settings on the monitor (IV-M30)
Set the field network settings of the sensor to
[PROFINET].
1
Touch the [Sensor expansion settings]
button on the sensor settings menu screen.
2
Touch the [Environment setting] button,
followed by the [Network expansion
setting] button.
3
Touch the [Settings] button for the field
network.
4
Select [PROFINET] for the protocol.
5
Select [Enabled] if you wish to enable the
data handshake control.
y
If the protocol is set to [Disabled], the
settings will be greyed out and disabled.
y
If data handshake control has been set
to [Enabled], the status result will not be
updated until [Result acquisition complete
notice] (Address2, Bit0 of Command Control)
is input.
“Operating procedure of the data I/O
6
Once you have finished configuring the
settings, touch the [OK] button.
Data I/O communication setting method
5
Data I/O communication