5-4

- IV Series User’s Manual (Field Network) -

Data I/O communication setting method

When setting by IV-Navigator (IV-H1)

Set the field network settings of the sensor to
[PROFINET].

1

Open the sensor expansion settings screen.

2

Select the [Device settings] tab, and then

click the [Settings] button under [Field

network].

3

Select [PROFINET] in [Protocol] for the

field network.

Tick the checkbox if you wish to enable the
data handshake control.

y

If the protocol is set to [Disabled], the

settings will be greyed out and disabled.

y

If data handshake control has been set

to [Enabled], the status result will not be

updated until [Result acquisition complete

notice] (“Address2 Bit0” of Command Control)

is input.

“Operating procedure of the data I/O

communication” (Page 5-32)

4

When you have finished configuring the

settings, click the [OK] button.

You will return to the sensor expansion settings
screen.

5

Click the [OK] button.

You will return to the main screen of [Setting].

5

Data I/O communication