5-4
- IV Series User’s Manual (Field Network) -
Data I/O communication setting method
When setting by IV-Navigator (IV-H1)
Set the field network settings of the sensor to
[PROFINET].
1
Open the sensor expansion settings screen.
2
Select the [Device settings] tab, and then
click the [Settings] button under [Field
network].
3
Select [PROFINET] in [Protocol] for the
field network.
Tick the checkbox if you wish to enable the
data handshake control.
y
If the protocol is set to [Disabled], the
settings will be greyed out and disabled.
y
If data handshake control has been set
to [Enabled], the status result will not be
updated until [Result acquisition complete
notice] (“Address2 Bit0” of Command Control)
is input.
“Operating procedure of the data I/O
4
When you have finished configuring the
settings, click the [OK] button.
You will return to the sensor expansion settings
screen.
5
Click the [OK] button.
You will return to the main screen of [Setting].
5
Data I/O communication