z

„

Input Assembly Address 4 to 7: Status result

The Bits at Address 4 to 7 of the Input Assembly have the following functions:

Address

Bit

Item

Content

Data content

4

0

Overall judgment

Displays the overall status

result.

0 : NG 1 : OK

1

Position correction

Displays the position correction

result.

0 : NG 1 : OK

2

Logic 1

Displays the result of Logic 1.

0 : NG 1 : OK

3

Logic 2

Displays the result of Logic 2.

0 : NG 1 : OK

4

Logic 3

Displays the result of Logic 3.

0 : NG 1 : OK

5

Logic 4

Displays the result of Logic 4.

0 : NG 1 : OK

6 to 7 Reserved by system

---

---

5

0 to 7 Reserved by system

---

---

6

0

Tool 1

Displays the result of Tool 1.

0 : NG 1 : OK

1

Tool 2

Displays the result of Tool 2.

0 : NG 1 : OK

2

Tool 3

Displays the result of Tool 3.

0 : NG 1 : OK

3

Tool 4

Displays the result of Tool 4.

0 : NG 1 : OK

4

Tool 5

Displays the result of Tool 5.

0 : NG 1 : OK

5

Tool 6

Displays the result of Tool 6.

0 : NG 1 : OK

6

Tool 7

Displays the result of Tool 7.

0 : NG 1 : OK

7

Tool 8

Displays the result of Tool 8.

0 : NG 1 : OK

7

0

Tool 9

Displays the result of Tool 9.

0 : NG 1 : OK

1

Tool 10

Displays the result of Tool 10.

0 : NG 1 : OK

2

Tool 11

Displays the result of Tool 11.

0 : NG 1 : OK

3

Tool 12

Displays the result of Tool 12.

0 : NG 1 : OK

4

Tool 13

Displays the result of Tool 13.

0 : NG 1 : OK

5

Tool 14

Displays the result of Tool 14.

0 : NG 1 : OK

6

Tool 15

Displays the result of Tool 15.

0 : NG 1 : OK

7

Tool 16

Displays the result of Tool 16.

0 : NG 1 : OK

y

If the position correction/logic/tool is not set, the data content will be “0”.

y

If the status result of the tool is either “trigger standby” (no judgment) or “judgment not possible”, the
data content will be OFF (0).

3