beautypg.com

Status modules parameter details, Status modules parameter details -22, Command status bits address 0 – KEYENCE IV Series User Manual

Page 80: Control result (response) -22, Command status bits address 1, Control error result -22

background image

5-22

- IV Series User’s Manual (Field Network) -

Data allocations in the data I/O communication

Status Modules parameter details

z

„

Command Status Bits Address 0: Control result (response)

The Bits at Address 0 of the Command Status Bits have the following functions:

Address

Bit

Item

Content

Data content

0

0

Trigger response

Stores the external trigger

response.

0 : OFF

1 : ON

1

Master image registration

response

Stores the master image

registration response.

0 : OFF

1 : ON

2

Program switching

response

Stores the program switching

response.

0 : OFF

1 : ON

3

Warning clear response

Stores the warning clear

response.

0 : OFF

1 : ON

4

Statistics reset response Stores the statistics reset

response.

0 : OFF

1 : ON

5

Buffer clear response

Stores the buffer clear response. 0 : OFF

1 : ON

6 to 7 Reserved by system

---

---

z

„

Command Status Bits Address 1: Control error result

The Bits at Address 1 of the Command Status Bits have the following functions:

Address

Bit

Item

Content

Data content

1

0

Trigger failed

This bit is output when the

external trigger is unsuccessful.

0 : -

1 : The external trigger

has failed.

1

Master image registration

failed

This bit is output when the

master image registration is

unsuccessful.

0 : -

1 : Master image

registration has

failed.

2

Program switching failed

This bit is output when

the program switching is

unsuccessful.

0 : -

1 : Program switching

has failed.

3 to 7 Reserved by system

---

---

5

Data I/O communication