Output assembly (plc → iv series), Output assembly (plc → iv series) -19 – KEYENCE IV Series User Manual
Page 41
3-19
- IV Series User’s Manual (Field Network) -
Data allocation in the cyclic communication
Output Assembly (PLC → IV series)
Output Assembly are devices that write instructions from the PLC to the IV series.
The device map of the data allocated for the Output Assembly is as shown below.
These parameters are responsible for the control instructions for the IV series, clearing of warnings and
handshake control.
For details of each parameter, refer to “Output Assembly parameter details” (Page 3-20).
Address
Bit7
Bit6
Bit5
Bit4
Bit3
Bit2
Bit1
Bit0
0
Reserved by system
Buffer
clear
request
Statistics
reset
request
Warning
clear
request
Program
switching
request
Master
registration
request
Trigger
request
1
Reserved by system
2
Reserved by system
Result
acquisition
complete
notification
3
Reserved by system
4 - 5
Program No.
6 - 11
Reserved by system
3
Cyclic communication
- LR-TB2000 Series (12 pages)
- LR-TB5000 Series (12 pages)
- LR-ZB250AN/AP (4 pages)
- LR-ZB250AN/P (3 pages)
- LR-ZBxN/P Series (3 pages)
- LR-ZBxxB (3 pages)
- OP-85135 (1 page)
- PZ-G Series (2 pages)
- PZ-V/M (2 pages)
- PS-N10 Series (12 pages)
- PX-10 (10 pages)
- CZ-V21A(P) (10 pages)
- CZ-K1(P) (8 pages)
- CZ-V1 (8 pages)
- FS-N10 Series (6 pages)
- FS-N10 Series (116 pages)
- FS-N15CN (1 page)
- FU-93(Z) (2 pages)
- FU-V Series (2 pages)
- FS-V30 (6 pages)
- FU-A40 (1 page)
- NU/FS-N Series (16 pages)
- FS-V33(P) (8 pages)
- FS-V21 (4 pages)
- FS-V22 (4 pages)
- FS-V11(P) (4 pages)
- FS-V1(P) (4 pages)
- LV-N10 Series (12 pages)
- LV-N10 Series (112 pages)
- LV-S62 (1 page)
- OP-84350 (1 page)
- LV-SA (10 pages)
- LV-SB (12 pages)
- OP-87305 (1 page)
- LV Series (10 pages)
- LV-B102 (1 page)
- EV-108M(U) (1 page)
- EZ Series (1 page)
- EM Series (1 page)
- ES-M1(P) (3 pages)
- EX-V Series (120 pages)
- EX-500(W) Series (16 pages)
- GV Series (10 pages)
- IA Series (8 pages)
- LB-1000(W) (24 pages)