Rockwell automation plc, Description of the reference program, Description of the reference program ... a-7 – KEYENCE IV Series User Manual
Page 101

A-7
- IV Series User’s Manual (Field Network) -
Reference program (EtherNet/IP)
Rockwell Automation PLC
Rung0
Rung1
REQ
ONS
ONS
Program Change
MOV
Move
Source
Dest
Number
Program Number
REQ
Program Change
Program Change Ack
Description of the reference program
z
Rung0
This line sets “REQ” to ON and copies the Number data, which contains the program No. to be set, to the 
program No.
z
Rung1
Sets “REQ” to ON and executes “Program Change”. 
“Program Change Ack” ON will set “Program Change” to OFF (“Program Change” will be retained until 
“Program Change Ack” becomes ON). 
A
                    See also other documents in the category KEYENCE Sensors:                                                            
                    - LR-TB2000 Series (12 pages)
 - LR-TB5000 Series (12 pages)
 - LR-ZB250AN/AP (4 pages)
 - LR-ZB250AN/P (3 pages)
 - LR-ZBxN/P Series (3 pages)
 - LR-ZBxxB (3 pages)
 - OP-85135 (1 page)
 - PZ-G Series (2 pages)
 - PZ-V/M (2 pages)
 - PS-N10 Series (12 pages)
 - PX-10 (10 pages)
 - CZ-V21A(P) (10 pages)
 - CZ-K1(P) (8 pages)
 - CZ-V1 (8 pages)
 - FS-N10 Series (6 pages)
 - FS-N10 Series (116 pages)
 - FS-N15CN (1 page)
 - FU-93(Z) (2 pages)
 - FU-V Series (2 pages)
 - FS-V30 (6 pages)
 - FU-A40 (1 page)
 - NU/FS-N Series (16 pages)
 - FS-V33(P) (8 pages)
 - FS-V21 (4 pages)
 - FS-V22 (4 pages)
 - FS-V11(P) (4 pages)
 - FS-V1(P) (4 pages)
 - LV-N10 Series (12 pages)
 - LV-N10 Series (112 pages)
 - LV-S62 (1 page)
 - OP-84350 (1 page)
 - LV-SA (10 pages)
 - LV-SB (12 pages)
 - OP-87305 (1 page)
 - LV Series (10 pages)
 - LV-B102 (1 page)
 - EV-108M(U) (1 page)
 - EZ Series (1 page)
 - EM Series (1 page)
 - ES-M1(P) (3 pages)
 - EX-V Series (120 pages)
 - EX-500(W) Series (16 pages)
 - GV Series (10 pages)
 - IA Series (8 pages)
 - LB-1000(W) (24 pages)
 