Error code list, Error code list -29 – KEYENCE IV Series User Manual
Page 87
5-29
- IV Series User’s Manual (Field Network) -
Data allocations in the data I/O communication
Error code list
The following shows the list of error codes that are generated in the IV series.
Error
code
Content
Cause
Countermeasure
0
No error
---
---
1 - 32
Program No. xx
corruption error
y
A data error has occurred
in program No. xx.
y
The data corruption may
have occurred due to a
power-off while writing
settings data and/or due
to noise.
y
Initialize the program No. xx.
y
Switch on the power back ON.
y
Do not switch off the unit while the
settings are being saved.
y
If the error persists, contact your
nearest KEYENCE office.
75
Non-volatile memory
error (EEPROM)
y
A data error has occurred.
y
The data corruption may
have occurred due to a
power-off while writing
settings data and/or due
to noise.
y
Initialize the settings of this unit.
y
Switch on the power back ON.
y
Do not switch off the unit while the
settings are being saved.
y
If the error persists, contact your
nearest KEYENCE office.
76
Non-volatile memory
error (FLASHROM)
81-128
System error
An error may have
occurred in the sensor.
y
Switch on the power back ON.
y
If the error persists, contact your
nearest KEYENCE office.
y
If two or more errors are occurring at the same time, the error code of the highest priority error will be
displayed.
y
Greater the error code, higher the priority of the error will be.
5