Tool result modules parameter details, Tool result address 0 to 19 (tool information), Tool result modules parameter details -28 – KEYENCE IV Series User Manual
Page 86: Position adjust result, Address 0 to 19, Position correction information) -28, Tool result address 0 to 19, Tool information) -28
5-28
- IV Series User’s Manual (Field Network) -
Data allocations in the data I/O communication
Tool Result Modules parameter details
z
Position Adjust Result Address 0 to 19 (Position correction information)
The Bits at Address 0 to 19 of the Position Adjust Result have the following functions:
Address
Data
type*
Item
Content
Data content
0 to 1
WORD
Position correction tool
matching rate
Stores the matching rate of the
position correction tool.
0 to 100
2 to 3
WORD
Position correction tool
Matching rate MAX
Stores the maximum matching
rate value of the position
correction tool.
0 to 100
4 to 5
WORD
Position correction tool
Matching rate MIN
Stores the minimum matching
rate value of the position
correction tool.
0 to 100
6 to 7
WORD
Position correction tool
Threshold value
Stores the threshold value of the
position correction tool.
0 to 100
8 to 19
---
Reserved by system
---
---
* WORD :
Unsigned 16-bit integer
DWORD : Unsigned 32-bit integer
Maximum and minimum matching rate values of the position correction tool will be reset in the same
manner as the statistics information.
z
Tool Result Address 0 to 19 (Tool information)
The Bits at Address 0 to 19 of the Tool Result have the following functions:
Address
Data
type*
Item
Content
Data content
0 to 1
WORD
Tool 1 matching rate
Stores the matching rate of Tool 1. 0 to 999
2 to 3
WORD
Tool 1 matching rate MAX Stores the maximum matching
rate value of Tool 1.
0 to 999
4 to 5
WORD
Tool 1 matching rate MIN Stores the minimum matching
rate value of Tool 1.
0 to 999
6 to 7
WORD
Tool 1 lower limit value
Stores the lower threshold value
of Tool 1.
0 to 999
8 to 9
WORD
Tool 1 upper limit value
Stores the upper threshold
value of Tool 1.
0 to 999
10 to 19
---
Reserved by system
---
---
* WORD :
Unsigned 16-bit integer
DWORD : Unsigned 32-bit integer
Thereafter, the information of tool 2, 3, ... 16 will be assigned for each 20-byte Address of “Tool Result”.
y
Maximum and minimum matching rate values of the tool will be reset in the same manner as the
statistics information.
y
If the upper threshold value of the tool is not set, the data content of the tool’s upper limit value will be “65535”.
5
Data I/O communication