beautypg.com

Tool result modules parameter details, Tool result address 0 to 19 (tool information), Tool result modules parameter details -28 – KEYENCE IV Series User Manual

Page 86: Position adjust result, Address 0 to 19, Position correction information) -28, Tool result address 0 to 19, Tool information) -28

background image

5-28

- IV Series User’s Manual (Field Network) -

Data allocations in the data I/O communication

Tool Result Modules parameter details

z

„

Position Adjust Result Address 0 to 19 (Position correction information)

The Bits at Address 0 to 19 of the Position Adjust Result have the following functions:

Address

Data

type*

Item

Content

Data content

0 to 1

WORD

Position correction tool

matching rate

Stores the matching rate of the

position correction tool.

0 to 100

2 to 3

WORD

Position correction tool

Matching rate MAX

Stores the maximum matching

rate value of the position

correction tool.

0 to 100

4 to 5

WORD

Position correction tool

Matching rate MIN

Stores the minimum matching

rate value of the position

correction tool.

0 to 100

6 to 7

WORD

Position correction tool

Threshold value

Stores the threshold value of the

position correction tool.

0 to 100

8 to 19

---

Reserved by system

---

---

* WORD :

Unsigned 16-bit integer

DWORD : Unsigned 32-bit integer

Maximum and minimum matching rate values of the position correction tool will be reset in the same
manner as the statistics information.

z

„

Tool Result Address 0 to 19 (Tool information)

The Bits at Address 0 to 19 of the Tool Result have the following functions:

Address

Data

type*

Item

Content

Data content

0 to 1

WORD

Tool 1 matching rate

Stores the matching rate of Tool 1. 0 to 999

2 to 3

WORD

Tool 1 matching rate MAX Stores the maximum matching

rate value of Tool 1.

0 to 999

4 to 5

WORD

Tool 1 matching rate MIN Stores the minimum matching

rate value of Tool 1.

0 to 999

6 to 7

WORD

Tool 1 lower limit value

Stores the lower threshold value

of Tool 1.

0 to 999

8 to 9

WORD

Tool 1 upper limit value

Stores the upper threshold

value of Tool 1.

0 to 999

10 to 19

---

Reserved by system

---

---

* WORD :

Unsigned 16-bit integer

DWORD : Unsigned 32-bit integer

Thereafter, the information of tool 2, 3, ... 16 will be assigned for each 20-byte Address of “Tool Result”.

y

Maximum and minimum matching rate values of the tool will be reset in the same manner as the
statistics information.

y

If the upper threshold value of the tool is not set, the data content of the tool’s upper limit value will be “65535”.

5

Data I/O communication