5-17

- IV Series User’s Manual (Field Network) -

Data allocations in the data I/O communication

Status Modules (IV series → PLC)

Status Modules are modules that write responses from the IV series to the PLC.
The device map of the data allocated for the Status Modules is as shown below.
These parameters output the statuses, status results and statistics information of the IV series.
For details of each parameter, refer to “Status Modules parameter details” (Page 5-22).

z

„

Command Status Bits

Slot No.: 2
Module size: 4 bytes

Address

Bit7

Bit6

Bit5

Bit4

Bit3

Bit2

Bit1

Bit0

0

Reserved by system

Buffer

clear

response

Statistics

reset

response

Warning

clear

response

Program

switching

response

Master

registration

response

Trigger

response

1

Reserved by system

Program

switching

failed

Master

registration

failed

Trigger

failed

2

Reserved by system Ready

RUN

Imaging

status

BUSY

Result

update

complete

Result

available

3

Error

Warning

Buffer

overrun

Reserved by system

z

„

Device Result Bits

Slot No.: 3
Module size: 4 bytes

Address

Bit7

Bit6

Bit5

Bit4

Bit3

Bit2

Bit1

Bit0

0

Reserved by system

LOGIC4

LOGIC3

LOGIC2

LOGIC1

Position

correction

Overall

judgment

1

Reserved by system

2

Tool 8

Tool 7

Tool 6

Tool 5

Tool 4

Tool 3

Tool 2

Tool 1

3

Tool 16

Tool 15

Tool 14

Tool 13

Tool 12

Tool 11

Tool 10

Tool 9

5

Data I/O communication