Status modules (iv series → plc), Command status bits, Device result bits – KEYENCE IV Series User Manual
Page 75: Status modules (iv series → plc) -17, Command status bits -17, Device result bits -17
5-17
- IV Series User’s Manual (Field Network) -
Data allocations in the data I/O communication
Status Modules (IV series → PLC)
Status Modules are modules that write responses from the IV series to the PLC.
The device map of the data allocated for the Status Modules is as shown below.
These parameters output the statuses, status results and statistics information of the IV series.
For details of each parameter, refer to “Status Modules parameter details” (Page 5-22).
z
Command Status Bits
Slot No.: 2
Module size: 4 bytes
Address
Bit7
Bit6
Bit5
Bit4
Bit3
Bit2
Bit1
Bit0
0
Reserved by system
Buffer
clear
response
Statistics
reset
response
Warning
clear
response
Program
switching
response
Master
registration
response
Trigger
response
1
Reserved by system
Program
switching
failed
Master
registration
failed
Trigger
failed
2
Reserved by system Ready
RUN
Imaging
status
BUSY
Result
update
complete
Result
available
3
Error
Warning
Buffer
overrun
Reserved by system
z
Device Result Bits
Slot No.: 3
Module size: 4 bytes
Address
Bit7
Bit6
Bit5
Bit4
Bit3
Bit2
Bit1
Bit0
0
Reserved by system
LOGIC4
LOGIC3
LOGIC2
LOGIC1
Position
correction
Overall
judgment
1
Reserved by system
2
Tool 8
Tool 7
Tool 6
Tool 5
Tool 4
Tool 3
Tool 2
Tool 1
3
Tool 16
Tool 15
Tool 14
Tool 13
Tool 12
Tool 11
Tool 10
Tool 9
5
Data I/O communication