- IV Series User’s Manual (Field Network) -

Cyclic communication setting method

Keyence KV series settings

This following explains the setting method when
using KV-5500.
For details of the required setting, such as the unit
configuration for the PLC and the KV STUDIO
settings for connecting with the PC, refer to the “KV
STUDIO User’s Manual” and the “KV-EP21V User’s
Manual”.

1

Right-click KV-5500 in the unit editor of

KV STUDIO, and then select [EtherNet/IP

setting].

2

Drag [IV Series] from the Unit list and add

it to the scan list.

3

Set the Node address and IP address

for the IV series on the [Initial adapter

settings] screen.

4

Modify the settings as necessary.

Click the connection name in the scan list.

The [Connection settings] screen will appear.

z

z

Connection name

Select [Monitor/External input] or [Monitor data].

z

z

RPI (communication cycle)

You can set the cyclic communication cycle.

z

z

Connection type

Select [Point-to-point] or [Multicast].

5

Save the settings and close [EtherNet/IP

settings] and the unit editor.

3

Cyclic communication