Sample trigs, Trigless locks, Trigless trigs – Elektron Octatrack User Manual
Page 92: One shot trigs

PATTERNS
80
SAMPLE TRIGS
Sample trigs trig the machine of the track, making the sample assigned to the machine 
play. Enter by simply pressing a [TRIG] key. Sample trigs are indicated by red 
LEDs.
TRIGLESS LOCKS
Trigless locks do not trig machines, LFOs or FX envelopes. Enter them by pressing 
[FUNCTION] + [TRIG]. 
Trigless locks are indicated by half-bright green 
trigs can be turned to trigless locks by pressing [TRIG] + [EXIT/NO] twice. To turn a trigless 
lock to a trigless trig, press [TRIG] + [ENTER/YES]. When pressing the [TRIG] key of a tri-
gless lock, it will turn into a sample trig. Press the [TRIG] key again to remove the sample 
trig altogether.
When in LIVE RECORDING mode and changing lockable parameters, trigless locks con-
taining the locked parameters will be entered on the sequencer by default.
TRIGLESS TRIGS
Trigless trigs function similarly to trigless locks, but trig LFOs and FX envelopes. They can 
only be applied by converting sample trigs or trigless locks. 
Trigless trigs are indicated by green full-bright 
trig can be turned to a trigless trig by pressing [TRIG] + [EXIT/NO]. To turn a trigless lock to 
a trigless trig, press [TRIG] + [ENTER/YES]. When pressing the [TRIG] key of a trigless 
trig, it will turn into a sample trig. Press the [TRIG] key again to remove the sample trig alto-
gether.
ONE SHOT TRIGS
One shot trigs trig a sample or a track recorder only once. They are especially useful when 
using the Octatrack as a backing track machine, as they for example can trig very long 
Static samples without retrigging them once the pattern loops. This trig type is also availa-
ble to recorder trigs. One shot trigs are not available to MIDI tracks. 
If a track contains several one shot trigs, all one shot trigs of that track will be disarmed 
once one of the one shot trigs has been activated by the sequencer. This extends to the 
tracks of other patterns as well. If a one shot trig has been trigged on track 1 of pattern A01, 
any one shot trigs on the first track of patterns A02-P16 will also be disarmed.
One shot trigs are entered by pressing [FUNCTION] + the [TRIG] key of an existing sam-
ple trig. The 
one shot trig. One shot trigs that have been activated by the sequencer are indicated by 
alternating yellow and red 
sequencer is stopped, power cycling the Octatrack or changing projects will re-arm all one 
shot trigs. The [STOP] + [STOP] behavior can be disabled in the PERSONALIZE menu. 
Read more on page 33.
There exists several ways of arming and disarming one shot trigs. While in GRID 
RECORDING mode and either the RECORDING SETUP menus or the TRACK TRIG EDIT 
menu with REC TRIG chosen, is active, all one shot recorder trigs of the active track will be 
re-armed when pressing [ENTER/YES]. The text “ARM REC TRK” will be visible. The one 
shot recorder trigs will keep re-arming for as long as the key is held. Note that one shot 
sample trigs will not be affected. This way of arming and disarming can be disabled in the 
PERSONALIZE menu. Read more on page 32.