ANLG will not necessarily make the envelope start from zero once a sample is
being trigged. Instead, when a sample is trigged the envelope attack will start from
the current envelope level.

RTRG will make the amplitude envelope start from zero every time a sample is
being trigged.

R+T will make the amplitude envelope start from zero every time a sample trig or a
trigless trig is activated by the sequencer.

TTRG will not necessarily make the envelope start from zero once a sample trig or
a trigless trig is activated by the sequencer. Instead, when a sample or a trigless trig
is activated the envelope attack will start from the current envelope level.

SYNC sets if the amplitude envelope should be synced to the Octatrack BPM or not.

ATCK sets how the attack of the envelope should behave.

LIN will make the envelope attack work in a linear fashion.

LOG will make the envelope attack work in an exponential fashion. This setting
allows for more smooth fade ins.

FX1 controls how the envelope will affect the multi mode filter or the amplitude modulator
when either of these effects are assigned to effect block 1.

ANLG will, if the multi mode filter is assigned to effect 1, not necessarily make the
filter envelope start from zero once a sample trig is being trigged. Instead, the filter
envelope attack will start from the current envelope level. If the amplitude modulator
is assigned to effect 1 the phase will be restarted each time a sample trig is trigged.

RTRG will, if the multi mode filter is assigned to effect 1, make the filter envelope
start from zero every time a sample trig is being trigged. If the amplitude modulator is
assigned to effect 1 the phase will be restarted each time a sample trig is trigged.

R+T will, if the multi mode filter is assigned to effect 1, make the filter envelope start
from zero every time a sample trig or a trigless trig is activated by the sequencer. If
the amplitude modulator is assigned to effect 1 the phase will be restarted each time
a sample trig or a trigless trig is being activated.

TTRG will, if the multi mode filter is assigned to effect 1, not necessarily make the
filter envelope start from zero once a sample trig or a trigless trig is activated by the
sequencer. Instead, the filter envelope attack will start from the current envelope
level. If the amplitude modulator is assigned to effect 1 the phase will be restarted
each time a sample trig or a trigless trig is being activated.

FX2 works just like FX1 parameter. It only affects the multi mode filter or amplitude modula-
tor when either of these effects are assigned to the second effects slot.

FX1 and FX1 AMP SETUP parameters are the only TRACK PAGE parameters, apart
from the EFFECT pages, that are available to a master track.